Navegando por Palavras-chave "Ponte cardiopulmonar"
Agora exibindo 1 - 4 de 4
Resultados por página
Opções de Ordenação
- ItemAcesso aberto (Open Access)Experiência inicial da Universidade Federal de São Paulo no desenvolvimento e aplicação do implante valvar aórtico transcateter(Universidade Federal de São Paulo (UNIFESP), 2009-11-25) Santos, Diego Felipe Gaia dos [UNIFESP]; Fonseca, José Honório de Almeida Palma da [UNIFESP]; Universidade Federal de São Paulo (UNIFESP)OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation has been viable, with lower morbidity and mortality. The aim of this study was to develop a national catheter-mounted aortic bioprosthesis for aortic position implant. METHOD: After animal studies, 14 patients with high EuroSCORE underwent transcatheter aortic valve implantation. Median age was 75,5 years. Median Logistic EuroSCORE was 43,7%. Four patients presented with disfunctional bioprosthesis, remainig ones presented calcified aortic stenosis (peak transvalvular gradient 79,7 mmHg). After minithoracotomy and under echocardiograph and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiograph and angiograph controls were performed and the patients were referred to ICU. RESULTS: Implant was feasible in 13 cases. There were no intra-operative deaths. Mortality was 42%. Median peak transvalvular aortic gradient reduced to 25,0 mmHg, and left ventricular function improved in the first 7 post operative days. Paravalvular aortic regurgitation was mild and present in most cases. Platelet count significantly decreased after procedure, but returned to normal values after 30 days. CONCLUSION: The transapical implantation of catheter-mounted bioprosthesis was a feasible procedure. Technical details and learning curve require further discussion.
- ItemAcesso aberto (Open Access)Implante transapical de endoprótese valvada balão-expansível em posição aórtica sem circulação extracorpórea(Sociedade Brasileira de Cirurgia Cardiovascular, 2009-06-01) Gaia, Diego Felipe [UNIFESP]; Fonseca, José Honório de Almeida Palma da [UNIFESP]; Souza, José Augusto Marcondes de [UNIFESP]; Guilhen, José Cícero Stocco [UNIFESP]; Telis, Andre [UNIFESP]; Fischer, Claudio Henrique [UNIFESP]; Ferreira, Carolina Baeta Neves Duarte [UNIFESP]; Buffolo, Enio [UNIFESP]; Universidade Federal de São Paulo (UNIFESP)OBJECTIVE: The aortic valve replacement is a routine procedure, and involves replacement of the native valve/prosthesis. In most of the patients who undergo such procedure the risk is acceptable, but in some cases, such risk can justify contraindication. The minimally invasive transcatheter aortic valve implantation without cardiopulmonary bypass (CPB) has been shown to be viable, with lower morbidity and mortality. The aim of this study was to develop a catheter-mounted aortic bioprosthesis for implantation without CPB. METHODS: After developing in animals, three patients with high EuroSCORE underwent implantation. Case 1: patients with bioprosthesis dysfunction; Case 2: severe aortic stenosis; Case 3: dysfunction of aortic bioprosthesis. After minithoracotomy and under echocardiographic and fluoroscopic control, a balloon catheter was placed on aortic position and inflated. After, a second balloon with valved endoprosthesis was positioned and released under high ventricular rate. Echocardiographic and angiographic controls were performed and the patients were referred to ICU. RESULTS: In the first case, implantation without CPB was possible with appropriate results. The patient evolved with improvement of ventricular function. After, this patient developed bronchopneumonia, tracheoesophageal fistula and died due to mediastinitis. Autopsy confirmed proper valve positioning and leaflets preservation. The second case showed the device migration after inflation of the balloon, with the need for urgent median sternotomy, CPB and conventional valve replacement. This patient evolved well and was discharged from the ICU on the 14th postoperative day without complications. This patient developed respiratory infection, septic shock and died on the 60th postoperative day. The patient from the third case underwent successful implantation. CONCLUSION: The off-pump transapical implantation of catheter-mounted bioprosthesis was shown to be a feasible procedure. Technical details and learning curve require further discussion.
- ItemAcesso aberto (Open Access)Implante transcateter de valva aórtica: resultados atuais do desenvolvimento e implante de um nova prótese brasileira(Sociedade Brasileira de Cirurgia Cardiovascular, 2011-09-01) Gaia, Diego Felipe [UNIFESP]; Fonseca, José Honório de Almeida Palma da [UNIFESP]; Ferreira, Carolina Baeta Neves Duarte [UNIFESP]; Souza, José Augusto Marcondes de [UNIFESP]; Gimenes, Marcus Vinícius [UNIFESP]; Macedo, Murilo Teixeira [UNIFESP]; Martins, Márcio Rodrigo [UNIFESP]; Buffolo, Enio [UNIFESP]; Universidade Federal de São Paulo (UNIFESP)OBJECTIVE: Aortic valve replacement is a routine procedure with acceptable risk, but in some cases, such risk can justify contraindication. Minimally invasive transcatheter aortic valve implantation has emerged as an alternative, with lower morbidity and mortality. The aim of this study was clinical, safety and efficacy assessment. METHODS: Thirty-three high risk patients underwent transcatheter balloon expandable aortic valve implantation. Mean Logistic EuroScore risk was 39.30% and STS score 30.28%. Eight patients presented with dysfunctional bioprosthesis, remaining ones presented calcified aortic stenosis. Procedures were performed in a hybrid OR under fluoroscopic and echocardiography guidance. Using a left minithoracotomy the prosthesis were implanted trough the ventricular apex under rapid ventricular pacing or hemorrhagic shock. Echocardiographic and angiographic controls were performed. RESULTS: Implant was feasible in 30 cases. Three conversions occured. There was only one case of operative death. Median transvalvular aortic gradient reduced from 43.58 mmHg to 10.54 mmHg. Left ventricular function improved in the first 7 postoperative days. Paravalvular aortic regurgitation was mild and present in 30.30%. One case presented major vascular complication and another one permanent pacemaker implant. One major stroke case occurred. Overall 30-day mortality was 18.18%. CONCLUSION: The transapical implantation of catheter mounted bioprosthesis is a safe procedure with acceptable midterm results. Long term follow-up with increased sample power is mandatory in order to access hemodynamic, life quality and survival
- ItemAcesso aberto (Open Access)Implante valve-in-valve transcateter em posição aórtica: uma mudança de seleção?(Sociedade Brasileira de Cirurgia Cardiovascular, 2012-09-01) Gaia, Diego Felipe [UNIFESP]; Couto, Aline [UNIFESP]; Breda, João Roberto [UNIFESP]; Ferreira, Carolina Baeta Neves Duarte [UNIFESP]; Macedo, Murilo Teixeira [UNIFESP]; Gimenes, Marcus Vinicius [UNIFESP]; Buffolo, Enio [UNIFESP]; Fonseca, José Honório de Almeida Palma da [UNIFESP]; Universidade Federal de São Paulo (UNIFESP)OBJECTIVE: Aortic valve replacement for bioprosthesis dysfunction is a procedure involving considerable risk. In some cases, mortality is high and may contraindicate the procedure. Minimally invasive transcatheter aortic valve-in-valve implant appears to be an alternative, reducing morbidity and mortality. The objective is to evaluate aortic valve-in-valve procedure using Braile Inovare prosthesis. METHODS: The Braile Inovare prosthesis, transcatheter, expandable balloon, was used in 14 cases. Average EuroSCORE was 42.9%. All patients had double aortic bioprosthesis dysfunction. Procedures were performed in a surgical hybrid environment under echocardiographic and fluoroscopic guidance. Using left minithoracotomy prostheses were implanted through the ventricular apex under high-frequency ventricular pacing. Serial clinical and echocardiographic controls were performed. Follow-up ranged 1-30 months. RESULTS: Correct prosthetic deployment was obtained in all cases. There was no conversion. There was no operative mortality. The 30-day mortality was 14.3% (two cases). Ejection fraction increased significantly after the 7th postoperative day. Aortic gradient significantly reduced. The residual aortic regurgitation was not present. There were no vascular complications or complete atrioventricular block. CONCLUSION: The transcatheter valve-in-valve procedure for bioprosthesis dysfunction is safe with low morbidity. This possibility may change prosthesis choice during the first aortic valve replacement, favoring bioprostheses.