Preparation and characterization of maleic anhydride grafted poly (hydroxybutirate-co-hydroxyvalerate) - phbv-g-ma

dc.contributor.authordo Amaral Montanheiro, Thais Larissa [UNIFESP]
dc.contributor.authorPassador, Fabio Roberto [UNIFESP]
dc.contributor.authorde Oliveira, Mauricio Pinheiro [UNIFESP]
dc.contributor.authorDuran, Nelson
dc.contributor.authorLemes, Ana Paula [UNIFESP]
dc.date.accessioned2019-01-21T10:30:01Z
dc.date.available2019-01-21T10:30:01Z
dc.date.issued2016
dc.description.abstractA compatibilizer agent was successfully produced by grafting maleic anhydride (MA) to poly(hydroxybutyrate-co-hydroxyvalerate) (PHBV) chains on a reactive processing by mechanical mixing, using a mixture of PHBV, MA and dicumyl peroxide (DCP) as initiator. The resulting PHBV grafted MA. (PHBV-g-MA) was characterized by Fourier transform infrared (FTIR) spectroscopy, thermogravimetric analysis (TGA), differential scanning calorimetry (DSC) and gel permeation chromatography (GPC), and its properties were compared to neat PHBV. FTIR showed an absorption band at 699 cm(-1) for PHBV-g-MA, related to CH group of grafted anhydride ring. The initial thermal degradation temperature of the compatibilizer agent was reduced when compared to neat PHBV. DSC analysis showed that after grafting MA onto PHBV the crystallization temperature was about 20 degrees C higher than neat PHBV, and the degree of crystallinity was increased. GPC analysis showed that MA when grafted onto PHBV led to a reduction of molecular weight and polydispersity.en
dc.description.affiliationInstituto de Ciência e Tecnologia , Universidade Federal de São Paulo - UNIFESP, Rua Talim, 330, CEP: 12231-280, São José dos Campos, SP, Brazil
dc.description.affiliationInstituto de Química, Universidade Estadual de Campinas - UNICAMP, CP 6154, Rua Carlos Gomes, 241, CEP: 13083-970, Campinas, SP, Brazil
dc.description.affiliationLaboratory on Nanostructures Synthesis and Biological Interactions - NanoBioss, Universidade Estadual de Campinas - UNICAMP, Rua Carlos Gomes, 241, CEP: 13083-970, Campinas, SP, Brazil
dc.description.affiliationUnifespInstituto de Ciência e Tecnologia , Universidade Federal de São Paulo - UNIFESP, Rua Talim, 330, CEP: 12231-280, São José dos Campos, SP, Brazil
dc.description.sourceWeb of Science
dc.description.sponsorshipBrazilian Funding institution CAPES
dc.description.sponsorshipBrazilian Funding institution FAPESP
dc.format.extent229-235
dc.identifierhttp://dx.doi.org/10.1590/1980-5373-MR-2015-0496
dc.identifier.citationMaterials Research-Ibero-American Journal Of Materials. Sao carlos, v. 19, n. 1, p. 229-235, 2016.
dc.identifier.doi10.1590/1980-5373-MR-2015-0496
dc.identifier.fileS1516-14392016000100229.pdf
dc.identifier.issn1516-1439
dc.identifier.scieloS1516-14392016000100229
dc.identifier.urihttp://repositorio.unifesp.br/handle/11600/49540
dc.identifier.wosWOS:000374205900030
dc.language.isoeng
dc.publisherUniv fed sao carlos, dept engenharia materials
dc.relation.ispartofMaterials Research-Ibero-American Journal Of Materials
dc.rightsinfo:eu-repo/semantics/openAccess
dc.subjectPoly(Hydroxybutyrate-Co-Hydroxyvalerate)en
dc.subjectMaleic Anhydrideen
dc.subjectGraf Copolymeren
dc.subjectCompatibilizeren
dc.subjectBiopolymerMaleated Poly(3-Hydroxybutyrate)en
dc.subjectFtir Spectroscopyen
dc.subjectCarbon Nanotubeen
dc.subjectNanocompositesen
dc.subjectPolypropyleneen
dc.subjectCrystallizationen
dc.subjectCompositesen
dc.subjectFunctionalizationen
dc.subjectPolyethyleneen
dc.subjectMorphologyen
dc.titlePreparation and characterization of maleic anhydride grafted poly (hydroxybutirate-co-hydroxyvalerate) - phbv-g-maen
dc.typeinfo:eu-repo/semantics/article
Arquivos
Coleções