The use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera (R) scleral contact lens fitting process

dc.citation.issue2
dc.citation.volume39
dc.contributor.authorWeber, Sarah La Porta [UNIFESP]
dc.contributor.authorAmbrosio Junior, Renato [UNIFESP]
dc.contributor.authorLipener, Cesar [UNIFESP]
dc.contributor.authorCoral-Ghanem, Cleusa
dc.contributor.authorHofling-Lima, Ana Luisa [UNIFESP]
dc.coverageAmsterdam
dc.date.accessioned2020-07-22T13:23:20Z
dc.date.available2020-07-22T13:23:20Z
dc.date.issued2016
dc.description.abstractPurpose: To test for associations between Pentacam (R) derived topography variables and to evaluate the predictive power of those variables in relation to scleral contact lens (SCL) fit. Setting: Department of Ophthalmology and Visual Sciences, Federal University of Sao Paulo, Sao Paulo-SP, Brazil. Design: Prospective observational non-randomised, non-comparative study. Methods: Forty-seven patients (63 eyes) were indicated for the use of Esclera (R) SCL. All patients underwent Scheimpflug imaging before the initial SCL evaluation. The following parameters were measured by Pentacam (R): corneal elevations, thickness, density, and anterior chamber depth (ACD). Correlations between the SCL parameters and the Pentacam measurements were analysed with Pearson's correlation coefficients. A simple linear regression model was created for each lens parameter using the most-correlated Pentacam variable. Results: In the total group, the results show correlations between the SCL parameters and the corneal astigmatism, ACD and pentacam-measured corneal height (Hm), with p < 0.001 each. In addition, an inverse correlation between the lens sagittal depth (LSD) and the anterior radii minimum was shown (p < 0.001). In the keratoconus group, the results show correlations between the SCL parameters and ACD and Hm (p < 0.001, each). An inverse correlation between the LSD and the total thickness corneal density average was also observed (p = 0.003). Conclusion: There was a positive correlation between the LSD and ACD, even as LD and ACD in the keratoconus group. Thus, these results suggest that certain Pentacam measurements can be good predictors of the most appropriate Esclera (R) lens to be fitted in keratoconus patients. (C) 2015 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.en
dc.description.affiliationUniv Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, SP, Brazil
dc.description.affiliationRenato Ambrosio Eye Inst, Rio De Janeiro, RJ, Brazil
dc.description.affiliationSadalla Amin Ghanem Eye Hosp, Joinville, SC, Brazil
dc.description.affiliationUnifespUniv Fed Sao Paulo, Dept Ophthalmol, Sao Paulo, SP, Brazil
dc.description.sourceWeb of Science
dc.format.extent148-153
dc.identifierhttp://dx.doi.org/10.1016/j.clae.2015.09.007
dc.identifier.citationContact Lens & Anterior Eye. Amsterdam, v. 39, n. 2, p. 148-153, 2016.
dc.identifier.doi10.1016/j.clae.2015.09.007
dc.identifier.issn1367-0484
dc.identifier.urihttps://repositorio.unifesp.br/handle/11600/56186
dc.identifier.wosWOS:000372680000010
dc.language.isoeng
dc.publisherElsevier Science Bv
dc.relation.ispartofContact Lens & Anterior Eye
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.subjectScleral lensesen
dc.subjectScieral lens fittingen
dc.subjectContact lensen
dc.subjectScheimpflug cameraen
dc.subjectKeratoconusen
dc.subjectDry eyeen
dc.titleThe use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera (R) scleral contact lens fitting processen
dc.typeinfo:eu-repo/semantics/article
Arquivos
Coleções