The N18 component of the median nerve SEP is not reduced by vibration

dc.contributor.authorManzano, G. M.
dc.contributor.authorNegrao, N.
dc.contributor.authorNobrega, JAM
dc.contributor.institutionUniversidade Federal de São Paulo (UNIFESP)
dc.contributor.institutionUniversidade de São Paulo (USP)
dc.date.accessioned2016-01-24T12:30:39Z
dc.date.available2016-01-24T12:30:39Z
dc.date.issued1998-09-01
dc.description.abstractObjective: To study the interference of mechanical vibration of the palm of the hand on the median nerve short-latency SEP components.Methods: Electrically-elicited short-latency median nerve SEP were obtained before and during mechanical vibration (120 Hz) of the palm in two groups of normal individuals (6 in group I and 9 in group II). the amplitude of the different components was compared between the two conditions through non-parametric statistical tests.Results: A significant reduction in the amplitude of the N9, P13/14 and N20 components was detected, however no overall significant changes were detected for the N18 component.Conclusions: Vibration interference reduced all studied components except the N18. these findings are interpreted as supporting evidence fur the proposed association between the N18 component and the inhibitory activities elicited in the dorsal column nuclei. (C) 1998 Elsevier Science Ireland Ltd. All rights reserved.en
dc.description.affiliationUNIFESP, Escola Paulista Med, Dept Neurol, Clin Neurophysiol Lab, BR-04120040 São Paulo, Brazil
dc.description.affiliationUniv São Paulo, Inst Biomed Sci, Dept Physiol & Biophys, São Paulo, Brazil
dc.description.affiliationUnifespUNIFESP, Escola Paulista Med, Dept Neurol, Clin Neurophysiol Lab, BR-04120040 São Paulo, Brazil
dc.description.sourceWeb of Science
dc.format.extent440-445
dc.identifierhttp://dx.doi.org/10.1016/S0168-5597(98)00010-0
dc.identifier.citationEvoked Potentials-electroencephalography and Clinical Neurophysiology. Clare: Elsevier Sci Ireland Ltd, v. 108, n. 5, p. 440-445, 1998.
dc.identifier.doi10.1016/S0168-5597(98)00010-0
dc.identifier.issn0168-5597
dc.identifier.urihttp://repositorio.unifesp.br/handle/11600/25952
dc.identifier.wosWOS:000076136900003
dc.language.isoeng
dc.publisherElsevier B.V.
dc.relation.ispartofEvoked Potentials-electroencephalography and Clinical Neurophysiology
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.rights.licensehttp://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy
dc.subjectsomatosensoryen
dc.subjectevoked potentialsen
dc.subjectmedian nerveen
dc.subjectsubcortical componentsen
dc.subjectvibrationen
dc.titleThe N18 component of the median nerve SEP is not reduced by vibrationen
dc.typeinfo:eu-repo/semantics/article
Arquivos