No changes in anatomical and functional glaucoma evaluation after trabeculectomy

dc.contributor.authorTavares, I. M.
dc.contributor.authorMelo, LAS
dc.contributor.authorPrata, J. A.
dc.contributor.authorGalhardo, R.
dc.contributor.authorParanhos, A.
dc.contributor.authorMello, PAA
dc.contributor.institutionUniversidade Federal de São Paulo (UNIFESP)
dc.contributor.institutionFed Univ Triangulo Mineiro
dc.date.accessioned2016-01-24T12:41:09Z
dc.date.available2016-01-24T12:41:09Z
dc.date.issued2006-05-01
dc.description.abstractTo assess the influence of glaucoma filtration surgery on anatomical and functional tests for glaucoma evaluation.Twenty-five eyes (25 patients) with primary open-angle glaucoma were evaluated, prospectively. Data were collected on vision acuity, intraocular pressure, standard automated perimetry, frequency doubling technology perimetry, scanning laser polarimetry (GDx) and confocal scanning laser ophthalmoscopy (HRT II) before and 3-6 months after surgery.Mean (+/- SD) pre- and postoperative visual acuities (logMAR) were 0.28 (+/- 0.18) and 0.30 (+/- 0.17), respectively (P=0.346). in a mean time of 4.5 (+/- 1.1) months after surgery, the mean preoperative intraocular pressure of 20.7 (+/- 5.4) mmHg decreased to 11.04 (+/- 2.52) mmHg (P < 0.001). the results of the standard automated perimetry, frequency doubling technology perimetry, scanning laser polarimetry and confocal scanning laser ophthalmoscopy diagnostic methods revealed no significant difference (P > 0.162) between pre and postoperative values and no significant correlation (P > 0.296) between intraocular pressure reduction and value changes.No significant change on any test variable was detected after glaucoma filtration surgery. Trabeculectomy does not appear to influence standard automated perimetry, frequency doubling technology perimetry, scanning laser polarimetry and confocal scanning laser ophthalmoscopy (HRT II) results after a 4.5-month period of surgery in early to moderate glaucoma.en
dc.description.affiliationUniversidade Federal de São Paulo, Dept Ophthalmol, Inst Visao, BR-04023062 São Paulo, Brazil
dc.description.affiliationFed Univ Triangulo Mineiro, Dept Ophthalmol, Uberaba, Brazil
dc.description.affiliationUnifespUniversidade Federal de São Paulo, Dept Ophthalmol, Inst Visao, BR-04023062 São Paulo, Brazil
dc.description.sourceWeb of Science
dc.format.extent545-550
dc.identifierhttp://dx.doi.org/10.1007/s00417-005-0104-6
dc.identifier.citationGraefes Archive for Clinical and Experimental Ophthalmology. New York: Springer, v. 244, n. 5, p. 545-550, 2006.
dc.identifier.doi10.1007/s00417-005-0104-6
dc.identifier.issn0721-832X
dc.identifier.urihttp://repositorio.unifesp.br/handle/11600/28876
dc.identifier.wosWOS:000237662500002
dc.language.isoeng
dc.publisherSpringer
dc.relation.ispartofGraefes Archive for Clinical and Experimental Ophthalmology
dc.rightsinfo:eu-repo/semantics/restrictedAccess
dc.rights.licensehttp://www.springer.com/open+access/authors+rights?SGWID=0-176704-12-683201-0
dc.subjectglaucomaen
dc.subjecttrabeculectomyen
dc.subjectimaging methodsen
dc.subjectvisual fieldsen
dc.subjectoptic discen
dc.subjectnerve fiber layeren
dc.titleNo changes in anatomical and functional glaucoma evaluation after trabeculectomyen
dc.typeinfo:eu-repo/semantics/article
Arquivos
Coleções