Ultrasonography for measuring rectus abdominis muscles diastasis
dc.contributor.author | Mendes, Denise de Almeida [UNIFESP] | |
dc.contributor.author | Nahas, Fabio Xerfan [UNIFESP] | |
dc.contributor.author | Veiga, Daniela Francescato | |
dc.contributor.author | Mendes, Fernando Vilela | |
dc.contributor.author | Figueiras, Ricardo Góes | |
dc.contributor.author | Gomes, Heitor Carvalho [UNIFESP] | |
dc.contributor.author | Ely, Pedro Bins | |
dc.contributor.author | Novo, Neil Ferreira [UNIFESP] | |
dc.contributor.author | Ferreira, Lydia Masako [UNIFESP] | |
dc.contributor.institution | Universidade Federal de São Paulo (UNIFESP) | |
dc.contributor.institution | UNIVAS | |
dc.contributor.institution | UNIVAS Surgery Department Plastic Surgery Division | |
dc.contributor.institution | Minas Center of Mastology and Imaging | |
dc.contributor.institution | UNIVAS Surgery Department Plastic Division | |
dc.contributor.institution | Santa Casa Plastic Surgery Unit | |
dc.date.accessioned | 2015-06-14T13:36:57Z | |
dc.date.available | 2015-06-14T13:36:57Z | |
dc.date.issued | 2007-06-01 | |
dc.description.abstract | PURPOSE: Preoperative imaging evaluation may be useful for determining the position of recti abdominis muscles before their correction. The purpose of this study is to evaluate the accuracy of ultrasonography to measure the width of rectus abdominis muscle diastasis. METHODS: Rectus diastasis was measured by ultrasonography preoperatively in 20 females. Rectus diastasis was measured in seven levels along the anterior rectus sheath by ultrasound after sustained deep inspiration and after expiration. Rectus diastasis, at the same levels, was also measured after its exposition during abdominoplasty by two independent observers, using a surgical compass. These values were compared using Wilcoxon's statistical text, for non independent values. RESULTS: There was no significant difference between the values obtained by ultrasound and those measured during surgery in the supra-umbilical levels and at the level of the umbilicus. However, below the umbilicus these values differed significantly, showing smaller values in the imaging evaluation. CONCLUSION: Ultrasonography is an accurate method to measure rectus diastasis above the umbilicus and at the umbilical level. | en |
dc.description.abstract | OBJETIVO: Estudos radiológicos pré-operatórios podem ser úteis para determinar a posição dos músculos retos do abdome antes de sua correção. O objetivo deste estudo é avaliar a acurácia da ultra-sonografia para medir a largura da diástase dos músculos retos do abdome. MÉTODOS: A diástase dos músculos retos foi medida pela ultra-sonografia, no pré-operatório em 20 mulheres. A diástase dos retos foi medida em sete níveis da bainha anterior dos retos foram examinados com ultra-som após inspiração profunda sustentada e após expiração. A diástase dos retos, nos mesmos níveis, foi também medida após sua exposição durante a abdominoplastia, por dois observadores independentes, usando compasso cirúrgico. As medidas foram comparadas usando o teste estatístico de Wilcoxon para dados não independentes. RESULTADOS: Não houve diferença significante entre as medidas ultra-sonográficas e intra-operatórias nos níveis supra-umbilicais e na cicatriz umbilical. Todavia, inferiormente à cicatriz umbilical, essas medidas diferiram significantemente sendo as ultra-sonográficas menores nestes pontos. CONCLUSÃO: A ultra-sonografia é um método acurado para medir a diástase de retos na região supra- umbilical e no nível do umbigo. | pt |
dc.description.affiliation | Federal University of São Paulo | |
dc.description.affiliation | UNIVAS | |
dc.description.affiliation | UNIFESP Surgery Department Plastic Surgery Division | |
dc.description.affiliation | UNIVAS Surgery Department Plastic Surgery Division | |
dc.description.affiliation | Minas Center of Mastology and Imaging | |
dc.description.affiliation | UNIVAS Surgery Department Plastic Division | |
dc.description.affiliation | UNIFESP | |
dc.description.affiliation | Santa Casa Plastic Surgery Unit | |
dc.description.affiliation | UNIFESP Biostatistics Department | |
dc.description.affiliation | UNIFESP Plastic Surgery Division | |
dc.description.affiliationUnifesp | UNIFESP, Surgery Department Plastic Surgery Division | |
dc.description.affiliationUnifesp | UNIFESP, Biostatistics Department | |
dc.description.affiliationUnifesp | UNIFESP, Plastic Surgery Division | |
dc.description.source | SciELO | |
dc.format.extent | 182-186 | |
dc.identifier | http://dx.doi.org/10.1590/S0102-86502007000300005 | |
dc.identifier.citation | Acta Cirurgica Brasileira. Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia, v. 22, n. 3, p. 182-186, 2007. | |
dc.identifier.doi | 10.1590/S0102-86502007000300005 | |
dc.identifier.file | S0102-86502007000300005.pdf | |
dc.identifier.issn | 0102-8650 | |
dc.identifier.scielo | S0102-86502007000300005 | |
dc.identifier.uri | http://repositorio.unifesp.br/handle/11600/3747 | |
dc.identifier.wos | WOS:000258573100005 | |
dc.language.iso | eng | |
dc.publisher | Sociedade Brasileira para o Desenvolvimento da Pesquisa em Cirurgia | |
dc.relation.ispartof | Acta Cirurgica Brasileira | |
dc.rights | info:eu-repo/semantics/openAccess | |
dc.subject | Abdominal Wall | en |
dc.subject | Abdominal Muscles | en |
dc.subject | Ultrasonography | en |
dc.subject | Diagnostic Imaging | en |
dc.subject | Surgery, Plastic | en |
dc.subject | Rectus Abdominis | en |
dc.subject | Parede Abdominal | pt |
dc.subject | Músculos Abdominais | pt |
dc.subject | Ultra-sonografia | pt |
dc.subject | Diagnóstico por Imagem | pt |
dc.subject | Cirurgia Plástica | pt |
dc.subject | Reto do Abdome | pt |
dc.title | Ultrasonography for measuring rectus abdominis muscles diastasis | en |
dc.title.alternative | Ultra-sonografia para medir a diástase dos músculos retos do abdome | pt |
dc.type | info:eu-repo/semantics/article |
Arquivos
Pacote Original
1 - 1 de 1
Carregando...
- Nome:
- S0102-86502007000300005.pdf
- Tamanho:
- 102.2 KB
- Formato:
- Adobe Portable Document Format
- Descrição: