Urea hydrogen peroxide determination in whole blood using europium tetracycline probe
dc.contributor.author | Courrol, Lilia C. | |
dc.contributor.author | Bellini, Maria H. | |
dc.contributor.author | Tarelho, Luiz V. G. | |
dc.contributor.author | Silva, Flavia R. O. | |
dc.contributor.author | Mansano, Ronaldo D. | |
dc.contributor.author | Gomes, Laercio | |
dc.contributor.author | Vieira, Nilson D. | |
dc.contributor.author | Shor, Nestor | |
dc.contributor.institution | FATEC SP | |
dc.contributor.institution | IPEN | |
dc.contributor.institution | Universidade de São Paulo (USP) | |
dc.contributor.institution | Universidade Federal de São Paulo (UNIFESP) | |
dc.date.accessioned | 2016-01-24T12:41:22Z | |
dc.date.available | 2016-01-24T12:41:22Z | |
dc.date.issued | 2006-08-01 | |
dc.description.abstract | We introduce the use of a lanthanide complex, tetracycline-europium, for the clinical diagnosis of urea hydrogen peroxide in human whole blood. the values obtained agree with the urea concentration variation verified in 49 patients, including 12 predialysis, 12 peritoneal, and 15 dialysis subjects, and 10 controls. This method is noninvasive and can help in the identification of renal and cardiac diseases. (c) 2006 Elsevier Inc. All rights reserved. | en |
dc.description.affiliation | FATEC SP, CEETEPS, São Paulo, Brazil | |
dc.description.affiliation | IPEN, CNEN SP, São Paulo, Brazil | |
dc.description.affiliation | EPUSP, LSI, São Paulo, Brazil | |
dc.description.affiliation | UNIFESP, Nefrol, São Paulo, Brazil | |
dc.description.affiliationUnifesp | UNIFESP, Nefrol, São Paulo, Brazil | |
dc.description.source | Web of Science | |
dc.format.extent | 140-144 | |
dc.identifier | http://dx.doi.org/10.1016/j.ab.2006.05.015 | |
dc.identifier.citation | Analytical Biochemistry. San Diego: Academic Press Inc Elsevier Science, v. 355, n. 1, p. 140-144, 2006. | |
dc.identifier.doi | 10.1016/j.ab.2006.05.015 | |
dc.identifier.issn | 0003-2697 | |
dc.identifier.uri | http://repositorio.unifesp.br/handle/11600/29066 | |
dc.identifier.wos | WOS:000239327000017 | |
dc.language.iso | eng | |
dc.publisher | Elsevier B.V. | |
dc.relation.ispartof | Analytical Biochemistry | |
dc.rights | info:eu-repo/semantics/restrictedAccess | |
dc.rights.license | http://www.elsevier.com/about/open-access/open-access-policies/article-posting-policy | |
dc.subject | lanthanides | en |
dc.subject | optical sensor | en |
dc.subject | glucose | en |
dc.subject | urea hydrogen peroxide | en |
dc.subject | tetracycline | en |
dc.subject | energy transfer | en |
dc.title | Urea hydrogen peroxide determination in whole blood using europium tetracycline probe | en |
dc.type | info:eu-repo/semantics/article |