Navegando por Palavras-chave "simulation"
Agora exibindo 1 - 5 de 5
Resultados por página
Opções de Ordenação
- ItemAcesso aberto (Open Access)Avaliação do desempenho de membranas de um sistema de osmose reversa para água de alimentação da caldeira(Universidade Federal de São Paulo, 2023-11-28) Silva, Caroline Neri dos Santos [UNIFESP]; Mahmoud Junior, Ricardo Marques [UNIFESP]; Pontes, Ricardo de Freitas Fernandes [UNIFESP]; Ribeiro, Kátia [UNIFESP]; http://lattes.cnpq.br/6490500674409303; http://lattes.cnpq.br/0337925215984741A água, recurso vital para todos os seres vivos, está se tornando cada vez mais escassa. Esta escassez é causada principalmente pelo aumento da poluição, degradação ambiental, alterações climáticas, entre outros. É importante entender formas de economizar esse recurso, como reaproveitar a água de um processo industrial para alimentar caldeiras industriais. Porém, existem alguns contratempos, pois a água que alimenta as caldeiras precisa ser desmineralizada, e para isso, podese utilizar a Osmose Reversa (OR), importante tratamento que remove sais dissolvidos, impurezas e contaminantes da água. Essa remoção ocorre por meio de membranas semipermeáveis, que permitem a passagem apenas da água purificada. Com isso, por meio de dados da água de alimentação da caldeira de uma empresa petroquímica, foi possível realizar uma análise de remoção sólidos totais dissolvidos, diminuição da dureza total, da condutividade e ajuste de pH para três diferentes tipos de membranas (BW30 PRO-400/34, BW30 XFRLE-400/34 e BW30-400) e assim, compreender qual das três apresenta melhor desempenho, segundo a ASME (Sociedade dos Engenheiros Mecânicos dos Estados Unidos) que determina o valor ótimo para esses parâmetros. As análises foram feitas para o sistema de OR instalado na empresa, usando o software WAVE (Dupont), que possibilita a inserção de dados iniciais, além da membrana desejada e retorna os dados informando como seria a saída dessa água após passagem pela Osmose Reversa. Como resultado, pode-se compreender que a melhor membrana seria a BW30 PRO-400/34 para a remoção de Na+, Mg2+, Cl-, SO42-, PO4 2-, SiO2 e STD, com uma contrapressão baixa de apenas 0,5 barg. Na associação de membranas, obteve-se bons resultados quando colocada a membrana BW30-400 no primeiro estágio e a membrana BW30-PRO 400/34 no segundo, contudo foi necessário colocar uma de 5 barg entre os estágios, algo que impossibilita a utilização dessa configuração visto o grande gasto energético e a deterioração das membranas com o passar do tempo. Para o sistema de membranas atualmente instalados na empresa (BW30-400), foi sugerida uma melhoria para extensão da vida útil, gerando menor desgaste e menor quantidade de lavagens químicas da OR, colocando uma contrapressão de 1 barg entre os estágios.
- ItemAcesso aberto (Open Access)Conhecimento e Tecnologias Visuais: Dimensão SócioTécnica, Linguagem e Limites do Humano.(Universidade Federal do Rio Grande do Sul, 2012-07) Parra, Henrique Zoqui Martins [UNIFESP]; http://lattes.cnpq.br/8314245614310718Analisaremos as dinâmicas sócio-políticas que pré-configuram o desenvolvimento das tecnologias de imagem e visão, tendo como foco a relação humano-máquina e as tendências informacionais e cibernéticas de superação do Humano. Tratase de uma abordagem teórica, que visa oferecer alternativas interpretativas às armadilhas da determinaçao tecnológica do social ou da neutralidade política da tecnologia. Na conclusão, apontamos como esses processos estão imbricados com um conflito político que tem os modos de subjetivação e as formas de conhecimento sensível como território atual de disputa.
- ItemSomente MetadadadosQuality assessment of a new surgical simulator for neuroendoscopic training(Amer Assoc Neurological Surgeons, 2011-04-01) Guimaraes Filho, Francisco Vaz [UNIFESP]; Coelho, Giselle; Cavalheiro, Sergio [UNIFESP]; Lyra, Marcos; Zymberg, Samuel Tau [UNIFESP]; Universidade Federal de São Paulo (UNIFESP); Curitiba Neurol Inst; Universidade Federal de Pernambuco (UFPE)Object. Ideal surgical training models should be entirely reliable, atoxic, easy to handle, and, if possible, low cost. All available models have their advantages and disadvantages. the choice of one or another will depend on the type of surgery to be performed. the authors created an anatomical model called the S.I.M.O.N.T. (Sinus Model Oto-Rhino Neuro Trainer) Neurosurgical Endotrainer, which can provide reliable neuroendoscopic training. the aim in the present study was to assess both the quality of the model and the development of surgical skills by trainees.Methods. the S.I.M.O.N.T. is built of a synthetic thermoretractable, thermosensible rubber called Neoderma, which, combined with different polymers, produces more than 30 different formulas. Quality assessment of the model was based on qualitative and quantitative data obtained from training sessions with 9 experienced and 13 inexperienced neurosurgeons. the techniques used for evaluation were face validation, retest and interrater reliability, and construct validation.Results. the experts considered the S.I.M.O.N.T. capable of reproducing surgical situations as if they were real and presenting great similarity with the human brain. Surgical results of serial training showed that the model could be considered precise. Finally, development and improvement in surgical skills by the trainees were observed and considered relevant to further training. It was also observed that the probability of any single error was dramatically decreased after each training session, with a mean reduction of 41.65% (range 38.7%-45.6%).Conclusions. Neuroendoscopic training has some specific requirements. A unique set of instruments is required, as is a model that can resemble real-life situations. the S.I.M.O.N.T. is a new alternative model specially designed for this purpose. Validation techniques followed by precision assessments attested to the model's feasibility. (DOI: 10.3171/2011.2.FOCUS10321)
- ItemSomente MetadadadosTechniques and Devices Used in Palpation Simulation with Haptic Feedback(Assoc Computing Machinery, 2016) Ribeiro, Mateus L.; Lederman, Henrique Manoel [UNIFESP]; Elias, Simone [UNIFESP]; Nunes, Fatima L. S.Palpation exam is a procedure in which a healthcare professional presses a specific region of a patient's body with the fingers in order to detect the presence of features and abnormalities under the skin. A simulator that aids the training of this procedure may contribute to the learning of the technique and the improvement of its implementation in real patients. This article presents a systematic review conducted in order to assess the state of the art of the simulation of the palpation procedure, providing a categorization of techniques and approaches used in systems with haptic feedback. The results indicate that there are existing gaps concerning the accessibility of the haptic devices, innovative methods to calculate force feedback and deformation caused by haptic devices, and user experience improvement, since most of the studies consider only one point of contact, which can limit the simulation realism.
- ItemSomente MetadadadosToward Community Standards and Software for Whole-Cell Modeling(Ieee-Inst Electrical Electronics Engineers Inc, 2016) Waltemath, Dagmar; Karr, Jonathan R.; Bergmann, Frank T.; Chelliah, Vijayalakshmi; Hucka, Michael; Krantz, Marcus; Liebermeister, Wolfram; Mendes, Pedro; Myers, Chris J.; Pir, Pinar; Alaybeyoglu, Begum; Aranganathan, Naveen K.; Baghalian, Kambiz; Bittig, Arne T.; Burke, Paulo Eduardo Pinto [UNIFESP]; Cantarelli, Matteo; Chew, Yin Hoon; Costa, Rafael S.; Cursons, Joseph; Czauderna, Tobias; Goldberg, Arthur P.; Gomez, Harold F.; Hahn, Jens; Hameri, Tuure; Gardiol, Daniel F. Hernandez; Kazakiewicz, Denis; Kiselev, Ilya; Knight-Schrijver, Vincent; Knuepfer, Christian; Koenig, Matthias; Lee, Daewon; Lloret-Villas, Audald; Mandrik, Nikita; Medley, J. Kyle; Moreau, Bertrand; Naderi-Meshkin, Hojjat; Palaniappan, Sucheendra K.; Priego-Espinosa, Daniel; Scharm, Martin; Sharma, Mahesh; Smallbone, Kieran; Stanford, Natalie J.; Song, Je-Hoon; Theile, Tom; Tokic, Milenko; Tomar, Namrata; Toure, Vasundra; Uhlendorf, Jannis; Varusai, Thawfeek M.; Watanabe, Leandro H.; Wendland, Florian; Wolfien, Markus; Yurkovich, James T.; Zhu, Yan; Zardilis, Argyris; Zhukova, Anna; Schreiber, FalkObjective: Whole-cell (WC) modeling is a promising tool for biological research, bioengineering, and medicine. However, substantial work remains to create accurate comprehensive models of complex cells. Methods: We organized the 2015 Whole-Cell Modeling Summer School to teach WC modeling and evaluate the need for new WC modeling standards and software by recoding a recently published WC model in the Systems Biology Markup Language. Results: Our analysis revealed several challenges to representing WC models using the current standards. Conclusion: We, therefore, propose several new WC modeling standards, software, and databases. Significance: We anticipate that these new standards and software will enable more comprehensive models.